Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Rev. chil. med. intensiv ; 25(1): 15-22, 2010. ilus, tab, graf
Artigo em Espanhol | LILACS | ID: lil-669730

RESUMO

Antecedentes: Existe evidencia que avala la utilidad de la ventilación mecánica no invasiva (VMNI) en el manejo de la insuficiencia respiratoria aguda (IRA), no obstante, la definición de variables que permitan predecir el éxito o fracaso de este recurso terapéutico es controversial. Objetivo: Evaluar el comportamiento de parámetros clínicos y de laboratorio en relación con el éxito o fracaso de la VMNI en pacientes con IRA. Metodología: Estudio prospectivo de cohorte descriptivo que incluye pacientes consecutivos que cumplieron con criterios de conexión a VMNI e ingresaron a la UPC de Clínica Alemana de Santiago entre marzo de 2005 y julio de 2007. Los pacientes se dividieron en dos grupos, aquellos que fracasan con VMNI y requirieron intubación, grupo fracaso (GF) y los que no la requirieron, grupo éxito (GE). Se registraron variables demográficas, APACHE II, diagnóstico de ingreso. La mecánica respiratoria, gasometría arterial y hemodinámica se obtuvieron en tres momentos de la evolución evolución: previo a la conexión, a las dos horas y al término del uso de VMNI (preintubación y destete de VMNI). Resultados: De los 132 pacientes incluidos se logró evitar la intubación en 99 de ellos (75 por ciento), 33 fueron intubados (25 por ciento), de los cuales 1 falleció. El pH fue menor en el GF (7,42+/-0,06 v/s 7,39+/-0,08; p =0,04). La saturación de oxígeno por pulsioximetría (SpO2) también fue menor en el GF tanto a las dos horas (96+/-2 v/s 95+/-3; p=0,01) como al final del uso de VMNI (96+/-2 v/s 95+/-3; p =0,04). La PaO2/FiO2 fue menor en el mismo grupo, en los tres momentos de medición: previo a la conexión (196+/-66 v/s 144+/-59; p =0,001), a las dos horas (223+/-92 v/s 179+/-88;p =0,022) y al término del uso de VMNI (252+/-78 v/s 208+/-104; p =0,021). Al final del uso de VMNI, tanto la frecuencia cardiaca (FC) (86+/-16 v/s 94+/-20; p =0,03) como el nivel de IPAP (12+/-2 v/s 13+/-3; p =0,02) fueron mayores en el GF. Conclusiones: El GF muestra..


Background: There is evidence supporting the benefits of non-invasive ventilation (NIV) in the treatment of acute respiratory failure (ARF), however, the role of different variables in the evaluation of this technique’s success are controversial. Objective: To evaluate the performance of the different clinical parameters and relate them with the success and failure of NIV in patients with ARF. Methodology: Prospective study of descriptive cohort that includes consecutive patients who fulfilled criteria of connection to NIV and entered to the ICU (Intensive Care Unit)of Clínica Alemana de Santiago between March of 2005 to July 2007. These patients were divided into two groups, those presenting failure with NIV and required intubation, failure group (GF) and those that did not require it, success sgroup (GE). The demographic registered variables measured were APACHE II, diagnosis of entrance were registered. The respiratory mechanics, arterial gasometry and haemodynamics were obtained at three moments of the evolution: previous to the connection, the two hours and at the end of the use of NIV (pre-intubation and weaning of NIV). Results: From the 132 patients included, intubation was avoided in 99 of them (75 percent) 33 percent were entubated from which only 1 died. The pH was lower in the FG (7.42 +/- 0.06v/s 7.39 +/- 0.08; p = 0.04). The oxygen saturation by pulsometry (SpO2), was also lower in the GF after two hours (96+/-2 v/s 95+/-3; p =0.01) and at the end of NIV use (96+/-2 v/s 95+/-3; p =0.04). The PaO2/FiO2 was lower in the same group, at the three moments of measurement: previous to the connection (196+/-66 v/s 144+/-59; p =0.001), two hours post connection (223+/-92 v/s 179+/-88; p =0.022) and at the end of the NIV use (252+/-78 v/s 208+/-104; p =0.021). At the end of the NIV use both, the cardiac frequency (FC) (86+/-16 v/s94+/-20; p =0.03) and the IPAP level (12+/-2 v/s 13+/-3; p=0.02)...


Assuntos
Humanos , Insuficiência Respiratória/terapia , Respiração Artificial/métodos , Doença Aguda , Gasometria , Unidades de Terapia Intensiva , Oxigênio/análise , Estudos Prospectivos , Valores de Referência
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...